Print this page

MPM700

 

The MPM700 is an Android based Patient Monitor with a 7" touch screen display. It has a built-in web server that makes it an IoT capable patient monitor that can be accessed by a web browser from anywhere.

  • EKG (5 leads)
  • Blood Pressure
  • Pulse/SPO2
  • Temperature
  • Weight (Bluetooth connected)
  • Blood Glucose Reader
  • Built in 110-200v power supply
  • USB input jack for any USB device 
  • USB output data jack.
  • Electronic Patient Record 

http://www.packetbio.com/uploads/images/MPM620-small.jpg

Price

USD 699.00 (includes 1 set of adult size accessories)

 

Specifications

 

ECG

  • measurement range: ±0.5mVp ~ ±5mVp
  • Heart Rate display range: 20bpm ~ 300bpm
  • Heart Rate display accuracy: ±2% or ±2bpm, whichever is greater.
  • Alarm delay time: <=12s
  • Input noise level for ECG amplifier: <=30uVp-p
  • Input impedance: >= 5M ohm (single ended)
  • CMRR (common mode rejection ratio): >=89dB
  • ECG bandwidth: 0.5~40Hz(monitoring mode), 0.05~75Hz(diagnostic mode)

 

SPO2

  • SpO2 measuring range: 35% ~ 99%
  • SpO2 measuring accuracy: Arms <=3% for SpO2 range from 70% to 100%
  • Pulse Rate measurement: 30~240bpm with 2% or ±2bpm accuracy
  • Update rate: 8 pulse beats
  • Low perfusion performance: Accuracy of SpO2 & PR still meets the declared
  • specification while the pulse amplitude modulation ratio is as low as 0.4%.

 

NIBP

  • Pneumatic pressure measurement: 0~300mmHg with ±3mmHg accuracy
  • Air leakage: <2mmHg/minute @ 300mmHg with 500cc cuff volume
  • Systolic pressure range: 40~270mmHg for adult, 40~200mmHg for pediatric
  • Diastolic pressure range: 10~210mmHg for adult, 10~150mmHg for pediatric
  • MAP range: 20~230mmHg for adult, 20~165mmHg for pediatric
  • BP accuracy: Mean error <= ±5mmHg, Standard deviation <= 8mmHg.
  • Pulse Rate measurement: 40~240bpm with 2% or ±2bpm accuracy
  • Blood pressure measuring time:< 30 sec. for typical adult (80/120mmHg, 75bpm) at manual or auto mode;
  • Time interval selection at auto mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes.
  • Over pressure protection with limit of 320±10mmHg by dual transducers

 

Respiration

  • Respiratory Rate measurement range: 0~120rpm
  • Respiratory Rate measurement accuracy: ±10%

 

Temperature

  • Temperature measurement range: 25.0~45.0 °C
  • Temperature measurement accuracy: ±0.2 °C
  • response time: <=30 sec.

 

Blood Sugar

  • measurement range from 20-600 ml/dl
  • 0.7μL Blood sample requirement
  • used strip detection
  • response time < 10secs

 

Body Weight

  • measurement range from 5kg-180kg
  • BMI Caliculations
  • Measurement in Lbs and Kgs.
  • Bluetooth enabled

 

Communication Support:

  • 3G​/GPRS packet data
  • Wifi (802.11 a/b/g)
  • USB connectivity to PC/Laptop

 

Display and Control Device:

  • Android Tablet
  • Laptop/PC
  • Mobile Phone